Knick P27000

Universal High Voltage Isolated Signal Transmitter

Knick Interface

  • 480 calibrated input ranges, +/- 0.02 to +/- 200 V or +/- 0.1 to +/- 100mA (unipolar/bipolar)
  • Output Signals: +/- 20 mA, +/- 10V, or 4…20 mA
  • Flexible set-up through onboard dipswitches
  • Galvanically isolated to 1000 V AC/DC (input and output channels), with test voltage of 5.4 kV AC
  • 10kHz Cut-off frequency
  • Response Time of 70 microseconds (T90)
  • Compact, 22.5 mm wide din-rail mountable housing

Details

The Knick P27000 compact universal signal conditioners can accommodate input signals from ±20mV to ±200V or ±20mA to ±100mA. 480 calibrated ranges are selectable using DIP switches.  3-way transformer based continuous isolation to 1000 V (input and output) provided in a very compact 12.5 mm housing.  Gain error of <0.08% of measured value helps ensure quality and accuracy of converted signal.

Knick’s P27000 High-Voltage Universal Signal Conditioner is a powerful solution for Test & Measurement. With its continuous isolation specification of 1000 V, it can pair with data acquisition systems (DAQ’s) in applications where the level of voltage protection needed is beyond the capability of the acquisition hardware.

There are an extensive number of input and output configurations available.

Specifications

Input Type
0 - 10 mV DC
0 - 50 mV DC
0 - 100 mV DC
0 - 1 V DC
±5 V DC
±10 V DC
±20 V DC
Output Type
±10 V DC
4 - 20 mA
±20 mA
Max Bandwidth
10 kHz
Isolation
Yes
Supply Power
20 - 28 V DC
80 - 250 V AC

Models

P27000
Universal Isolated Signal Conditioner

Downloads

P 27000